Shipping from 4 to 7 days - Permanent stock
Victron Energy MPPT 100/15 BlueSolar solar regulator for motorhomes and campers. - Ref. SCC010015200R
In stock Ships in 4-7 days
€127.70
VAT included
Reference
SCC010015200R

Description


Victron Energy MPPT 100/15 BlueSolar solar regulator for motorhomes and campers.

Maximum charge 15AH.

Ultra-fast Maximum Power Point Tracking (MPPT)

. Especially with cloudy skies, when the light intensity changes continuously, a lightning-fast MPPT controller will improve energy harvesting by up to 30%, compared to PWM charge controllers, and up to 10% compared to older MPPT controllers. slow.

Charge output The battery can be prevented from over-discharging by connecting all loads to the charge output.

This output will disconnect the load when the battery has discharged when it reaches a preset voltage.

You can also choose to set an intelligent battery management algorithm: see BatteryLife.

The load output is short-circuit proof. Some loads (especially inverters) can be connected directly to the battery, and the remote control of the inverter to the load output.

A special interface cable may be required; please refer to the manual. BatteryLife: intelligent battery management When a solar charge controller is not able to recharge the battery to full capacity in one day, what happens is that the battery cycles continuously between "partially charged" and "end of life" states. download".

This mode of operation (without periodic full recharge) will destroy a lead-acid battery in weeks or months.

The BatteryLife algorithm will monitor the state of charge of the battery and, if necessary, increase the load disconnect level day by day (i.e. it will disconnect the load sooner) until the collected solar energy is sufficient to recharge the battery up to almost 100%. From that point on, the load shedding level will modulate so that a near 100% recharge is achieved about once a week.

Programmable battery charging algorithm See the Support & Downloads > Software section on our website for more information.

Day/night timer and dimmer option See the Support & Downloads > Software section on our website for more information.

Programming and options for displaying real-time and history data - ColorControl GX or other GX devices: see the Venus documents on our website. - A smartphone or other Bluetooth-enabled device: the VE.Direct Bluetooth Smart dongle is required. BlueSolar MPPT 75/10, 75/15, 100/15, 100/20-48V charge controllers MPPT 75/15 solar charge controller BlueSolar MPPT 75/10 charge controller

BlueSolar MPPT 75/10 charge controller MPPT 75/15 MPPT 100/15 MPPT 100/20 Battery voltage (Auto selection) 12/24V 12/24/48V Nominal charge current 10A 15A 15A 20A Nominal PV power, 12V 1a ,b) 145W 220W 220W 290W Rated PV power, 24V 1a,b) 290W 440W 440W 580W Rated PV power, 48V 1a,b) nanana 1160W Maximum PV short-circuit current 2) 13A 15A 15A 20A Automatic load disconnection Yes Voltage open circuit maximum PV 75V 100V Maximum efficiency 98% Self-consumption 12V: 25 mA 24V: 15 mA 25 / 15 / 10 mA "Absorption" charge voltage 14.4V / 28.8V / 57.6V (adj.) "float" charging 13.8V / 27.6V (adjustable) 13.8V / 27.6V / 55.2V (adj.) Multi-phase adaptive charging algorithm Temperature compensation -16 mV / °C, -32 mV / ° C resp. Continuous charging current 15A 20A / 20A / 1A Low voltage load disconnection 11.1V/22.2V/44.4V or 11.8V/23.6V/47.2V or BatteryLife algorithm Low voltage load reconnection 13, 1V/26.2V/52.4V or 14V/28V/56V or BatteryLife algorithm Protection Output short circuit / Over temperature Working temperature -30 to +60°C (full rated power up to 40°C) Humidity 95%, no condensation VE.Direct data communication port (see the white paper on data communication on our website) HOUSING Color Blue (RAL 5012) Connection terminals 6 mm² / AWG10 Degree of protection IP43 (electronic components), IP22 (area of connection) Weight 0.5 kg 0.6 kg 0.65 kg Dimensions (H x W x D) 100 x 113 x 40 mm 100 x 113 x 50 mm 100 x 113 x 60 mm STANDARDS Safety EN/IEC 62109-1, UL 1741, CSA C22.2 1a) If more PV power is connected, the controller will limit the power input. 1b) The PV voltage must exceed Vbat + 5V for the controller to start. Once started, the minimum PV voltage will be Vbat + 1V. 2) A PV array with a higher short-circuit current may damage the controller.

See more
Cetelem